THE SINGLE BEST STRATEGY TO USE FOR DP50RB

The Single Best Strategy To Use For Dp50rb

The Single Best Strategy To Use For Dp50rb

Blog Article

Assist 4D probe; recognize the probe via the ID code; swap the 4D generate signal by using the  electrical relay to make the 4D probe perform Usually. four.2.two Principal board The key board could possibly be divided into two elements: entrance-end of the main board and back again-end of the most crucial board.

Dengan obshape baru yang cerdas dan desain layar penuh, mobilitas yang ditingkatkan, dan pengoperasian yang lebih nyaman, sistem yang andal dan terjangkau ini akan meningkatkan praktik umum dan sangat cocok untuk berbagai kebutuhan klinis.

Evaluating sufferers in right now’s demanding environment involves ground breaking technological innovation that permits clinicians to create swift and self-assured diagnoses. The flexibility from the DP-fifty expands your medical utility when assisting to strengthen affected person care.

The person will not be allowed to open the addresses and panel on the procedure, neither Be aware: machine disassemble is authorized. To ensure the system efficiency and safety, only Mindray engineers or engineers approved by Mindray can carry out routine maintenance.

By continuing your go to on our website, you happen to be consenting to our use of cookies. Having said that, it is possible to alter your cookie options Anytime.  Cookie preference Acknowledge and Move forward

Slash off cable ties connecting the principle unit to the Exhibit by diagonal reducing pliers, after which you can pull out the corresponding cable plugs.

Klik Setuju dan Lanjutkan untuk menyetujui cookie dan langsung menuju ke situs atau klik Informasi Selengkapnya untuk melihat deskripsi detail mengenai tipe cookie dan memilih apakah akan menyetujui cookie tertentu saat berada di situs ini.

Mindray’s new technology of black & white ultrasound process, DP-50 Specialist, is supplied with Highly developed imaging technologies making it possible for deeper penetration and a lot quicker picture acquisition with greater resolution.

Be aware: Ahead of uploading the log, be certain the ultrasound method is connected to network, or else, the program may possibly warn “could not connect to server” The server (smtp.

Soon after prosperous link, the newly included network printer identify might be proven within the printer driver record. Notice: Prior to join the network printer, be certain the ultrasound process as well as the printer are in exactly the same community area, along with the community is Functioning normally. The IP deal with as well as server name really should be legitimate, e.g. Webpage 47 DICOM Placing  Enter the AE Title of the ultrasound program, port and PDU in accordance with the actual predicament, and then click [OK] to exit the display screen.

Observe: On the keep an eye on, the brightness adjustment arrives before contrast. Just after readjusting the keep track of’s contrast and brightness, modify all preset and peripheral settings.

Take note: Ahead of inserting the connector in to the probe port, inspect the connector pin. When the pin is bent, never make use of the probe till it's been inspected / fixed / changed. Setting up Peripherals To the models with the supported peripherals, make sure you check Dp50rb with “two.

Soon after changing the CPU module, crucial file needs to be generated Once more based on the new MAC handle and created into HDD with the equipment. Or else, the configuration functionality from the merchandise will be lost. Right after taking away the CPU module, Remove panhead screws with washers (12 M3X6) fixed on the key unit box, you might take off the board. Web page 118 Figure eight-29 Disassemble the Control Panel Assembly (1) Keep the upper fringe of user interface assembly, and open up the user interface. Figure eight-30 Disassemble the User interface Assembly (2) Right after getting rid of 1 countersunk head self-tapping screw PT3X10 fixed around the user interface and just take out the plug on the keyboard and the most crucial unit connecting cables, you can remove the user interface assembly.

Efficiency Test five.5.one Test Process Resolution Detection depth Geometric Posture Precision Blackout location exam Document the Examination images 5.5.two Test Content The image utilised Here's only for reference, keep on with the graphic effect in the actual Be aware: predicament. Requirements: Display: established the distinction and brightness within the scientific application worth (or even the default status) Procedure ecosystem: dim area, simulating the medical software ecosystem. Web site seventy six In issue that the transverse resolution tests targets are horizontally exhibited, file the small distance of two targets that can be Evidently identified. Repeat the operation higher than with the transverse resolution screening targets at other depths. As shown in determine beneath. Axial resolution ... Webpage seventy seven When using the convex probe, maintain the transverse resolution tests targets to NOTE: be shown close to the midline. When using a linear probe with steer functionality, will not turn on the steer purpose when execute the transverse resolution test. Zoom in the region where by the targets located if important. The diameter from the focus on issue at a certain depth is equal on the transverse resolution in the depth. Site 78 5.

Click on Agree and Commence to just accept cookies and go on to the positioning or click on More Information to determine in depth descriptions of the categories of cookies and opt for no matter whether to accept certain cookies though on the location.

five.2.three Geometric positioning accuracy Longitudinal geometric positioning precision  Take a look at Phase: Do changes as how in testing the most depth. File the distance by 20mm each section around the longitudinal targets line utilizing the measurement caliper; Pick the worth with the greatest error (to 20mm), calculate the accuracy utilizing the formulation down below The measurement caliper really should be positioned on the higher fringe of the goal, Observe:... Webpage seventy nine Transverse geometric positioning precision  Test Action: Cover the scan surface area in the phantom with drinking water or pair gel, Carefully Make contact with the probe While using the scan surface Alter the depth, earning the transverse targets for being shown from the impression. Adjust the focus stage to get posited beside the transverse targets (the conventional isn't very clear) Alter parameters like achieve, TGC, building each transverse targets to become clearly exhibited. Web site eighty 5.five.2.4 Blackout Space Exam Action: Protect the scan surface area in the phantom with drinking water or couple gel, Carefully Get hold of the probe Along with the scan floor Modify the depth in a decrease value, and established the main target at the nearest place to the scan floor. Reduce the worth of parameters like AP, Achieve right up until the track record sounds just might be noticed. Web site 81: Program Update And Maintenance